Radioisotope Development & Production For Industrial & Medical Applications
I-131 MIBG
Product name
Sterile solution for injection
Pharmaceutical form
Specifications
I-131 Metaiodobenzylguanidine
Medical name
≥99%
Radionuclide purity
≥97%
Radiochemical purity
925-1110 MBq/mg
Specific activity
5.5 - 7
pH
8.02 days
Half life
333-410 MBq/ml
Activity concentration
1.85,3.7GBq
Available activity
Other Information
Treatment of neuroendocrine tumours, especially, phaeochromocytoma, neuroblastoma, paraganglioma, medullar thyroid carcinoma and carcinoid syndrome
Clinical application
Type A packaging
Packaging
≤ -18 º C
Storage
Weekly
Availability